Published October 28, 2021 | Version v1
Journal article Open

Enhancement-constrained acceleration: A robust reconstruction framework in breast DCE-MRI

  • 1. Washington University in St. Louis
  • 2. University of Chicago
  • 3. University of Washington

Description

In patients with dense breasts or at high risk of breast cancer, dynamic contrast enhanced MRI (DCE-MRI) is a highly sensitive diagnostic tool. However, its specificity is highly variable and sometimes low; quantitative measurements of contrast uptake parameters may improve specificity and mitigate this issue. To improve diagnostic accuracy, data need to be captured at high spatial and temporal resolution. While many methods exist to accelerate MRI temporal resolution, not all are optimized to capture breast DCE-MRI dynamics. We propose a novel, flexible, and powerful framework for the reconstruction of highly-undersampled DCE-MRI data: enhancement-constrained acceleration (ECA). Enhancement-constrained acceleration uses an assumption of smooth enhancement at small time-scale to estimate points of smooth enhancement curves in small time intervals at each voxel. This method is tested in silico with physiologically realistic virtual phantoms, simulating state-of-the-art ultrafast acquisitions at 3.5s temporal resolution reconstructed at 0.25s temporal resolution (demo code available here). Virtual phantoms were developed from real patient data and parametrized in continuous time with arterial input function (AIF) models and lesion enhancement functions. Enhancement-constrained acceleration was compared to standard ultrafast reconstruction in estimating the bolus arrival time and initial slope of enhancement from reconstructed images. We found that the ECA method reconstructed images at 0.25s temporal resolution with no significant loss in image fidelity, a 4x reduction in the error of bolus arrival time estimation in lesions (p < 0.01) and 11x error reduction in blood vessels (p < 0.01). Our results suggest that ECA is a powerful and versatile tool for breast DCE-MRI.

Data availability

All code will be available at https://github.com/tyo8/ECA_Demo A minimal data set, including run and error analysis scripts, are available at: https://figshare.com/projects/Enhancement-Constrained_Acceleration_ECA_/120072.

Files

journal.pone.0258621.pdf

Files (3.6 MB)

Name Size Download all
Article
md5:55871a15bd9b80ef45822939e93c08cf
3.5 MB Preview Download
Supporting information
md5:51ec563f0aaed951887e711c2c976293
79.4 kB Preview Download
md5:21dd17bf5fc4fe2267b80ae1ac607cb2
115.1 kB Preview Download

Additional details

Identifiers

DOI
10.1371/journal.pone.0258621
Other
oai:uchicago.tind.io:5897

Funding

National Science Foundation
DMS-165407
National Institutes of Health
5R01CA218700-04

UChicago Information

Division(s)
Biological Sciences Division, Physical Sciences Division
Department(s)
Radiology, Statistics