Published June 5, 2015 | Version v1
Journal article Open

A New Approach to Segment Both Main and Peripheral Retinal Vessels Based on Gray-Voting and Gaussian Mixture Model

  • 1. Central South University
  • 2. University of Chicago

Description

Vessel segmentation in retinal fundus images is a preliminary step to clinical diagnosis for some systemic diseases and some eye diseases. The performances of existing methods for segmenting small vessels which are usually of more importance than the main vessels in a clinical diagnosis are not satisfactory in clinical use. In this paper, we present a method for both main and peripheral vessel segmentation. A local gray-level change enhancement algorithm called gray-voting is used to enhance the small vessels, while a two-dimensional Gabor wavelet is used to extract the main vessels. We fuse the gray-voting results with the 2D-Gabor filter results as pre-processing outcome. A Gaussian mixture model is then used to extract vessel clusters from the pre-processing outcome, while small vessels fragments are obtained using another gray-voting process, which complements the vessel cluster extraction already performed. At the last step, we eliminate the fragments that do not belong to the vessels based on the shape of the fragments. We evaluated the approach with two publicly available DRIVE (Staal et al., 2004) and STARE (Hoover et at., 2000) datasets with manually segmented results. For the STARE dataset, when using the second manually segmented results which include much more small vessels than the first manually segmented results as the "gold standard," this approach achieved an average sensitivity, accuracy and specificity of 65.0%, 92.1% and 97.0%, respectively. The sensitivities of this approach were much higher than those of the other existing methods, with comparable specificities; these results thus demonstrated that this approach was sensitive to detection of small vessels.

Data availability

All relevant data are available within the paper and its supporting information files.

Files

journal.pone.0127748.pdf

Files (95.6 MB)

Name Size Download all
Article
md5:959300c0c43aae056dddc75b04f99d21
22.8 MB Preview Download
md5:d38e1e6d1cddd03fe1d8d7708841991d
72.7 MB Preview Download

Additional details

Identifiers

DOI
10.1371/journal.pone.0127748
Other
oai:uchicago.tind.io:9583

Funding

National Natural Science Foundation of China
81171420

UChicago Information

Division(s)
Biological Sciences Division
Department(s)
Radiology